Practice seminar: Decrease of spatial air-technical plants in accordance with DIN EN 12599

The way of planning over the building up to the start-up of spatial air-technical plants covers a complex building-technical knowledge. In accordance with VOB part of C � DIN 18379 must be accomplished after completion of a spatial air technical plant (RLT plant) an acceptance checking. This examination is a condition and basis for the decrease with the legal effects resulting in from it and on the part of owner and equipment manufacturer demands itself. The acceptance checking takes place after the European standard DIN EN 12599 � ventilation of buildings � test and measuring procedures for the delivery of inserted spatial air-technical plants �. The standard is valid for mechanically operated RLT plants, whose regulation is the preservation of a comfort condition in buildings. It is divided into check for completeness, functional tests as well as function measurements. The range of the examinations and measurements which can be accomplished at the plant becomes by 4 classes (A, B, C, D) specified. The choice of the class should be contractually agreed upon. Objective: In the context of the seminar it to learn to accomplish acceptance checkings and informed about the legal, normative defaults. On the basis the practical exercises you have the possibility of becoming acquainted with the normal use of the appropriate measuring instruments and of deepening these knowledge. The advisers lead you by the Abnahmeprozedere and give you hints and suggestions, in order your tasks more reliably would drive through shortly and/or to supervise to be able. Further the knowledge is arranged for you, which is necessary before a decrease, so that it comes to one � smooth � acceptance checking. In addition they receive references, how lack of an existing plant are to be eliminated. Contents of the seminar: � the usual measuring instruments and - muddled and use � antibugging by correct application of the appropriate measuring instruments � results of measurement know to interpret correct to evaluate and document surely � all necessary applicable laws, regulations, guidelines and standards for the decrease know � all steps of a normal acceptance checking to accomplish target group: Engineers and technical specialists from planning, execution, enterprise and monitoring, maintenance, management, Contracting in distribution companies, real estate economy and authorities, environmental and energy consultant seminar line: Professor Dr. - engineer Herbert Bley, college of further education Cologne, specialist area supply engineering/Institut TGA

This text was translated automatically.


Further information


VDI_Wissensforum
VDI Wissensforum GmbH
VDI-Platz 1
40468 Düsseldorf
Germany
Phone: +49 211 6214434
Fax: +49 211 6214154
email: wissensforum@vdi.de
Internet: http://www.vdi-wissensforum.de


Better informed: With YEARBOOK, NEWSLETTER, NEWSFLASH and EXPERT DIRECTORY

Stay up to date and subscribe to our monthly eMail-NEWSLETTER and our NEWSFLASH. Get additional information about what is happening in the world of cleanrooms with our printed YEARBOOK. And find out who the cleanroom EXPERTS are with our directory.

PPS ASYS Hydroflex Vaisala