Strong climate technology for hyperscale data centers

Ventilation device Vidur CoolCube from Weiss Klimatechnik

The Vindur CoolCube operates without a raised floor. This increases the capacity of a data center. (Image: Weiss Technik GmbH, own image)
The Vindur CoolCube operates without a raised floor. This increases the capacity of a data center. (Image: Weiss Technik GmbH, own image)

Hyperscale and high-density data centers are working with increasingly powerful servers. This creates new challenges due to extremely high heat loads. The IT cooling must be even more powerful and, if necessary, flexibly configurable. At the same time, it should offer high energy efficiency and operational security. The Vindur CoolCube from Weiss Klimatechnik meets these requirements.

The ventilation unit Vindur CoolCube enables simple, safe, and efficient cooling of the new server generations. It operates without a raised floor, allowing the capacity of a data center to be easily increased through larger racks. It can be installed as a standalone unit without complex structural measures. Its extensive configurability allows adaptation to a wide variety of requirements. Since Vindur CoolCubes operate independently of each other, using multiple units guarantees maximum fail-safety.

Strong cooling with low energy consumption

Vindur CoolCube is a powerful, chilled-water-based climate system for hyperscale and high-density data centers. Thanks to large heat exchangers and airflow optimized through CFD analyses, it ensures efficient cooling with minimal energy expenditure. The air handling units operate with horizontal airflow. They combine heat exchangers and fans in a single housing.

The compact Vindur CoolCubes are installed directly on the wall of the server room and require only one wall penetration for the supply air. The extraction of heated air is handled by other air handling units via a return air plenum from the warm aisle enclosures. These units are placed outside the server room; their maintenance is easily performed from the service corridor. The chilled-water units are ideally suited for connection to a chilled water plant or a central cooling system.


Weiss Klimatechnik GmbH
35447 Reiskirchen
Germany

Publications: Further publications by this company / author

Other articles under these categories: Building technology: Air conditioning


Better informed: With YEARBOOK, NEWSLETTER, NEWSFLASH, NEWSEXTRA and EXPERT DIRECTORY

Stay up to date and subscribe to our monthly eMail-NEWSLETTER and our NEWSFLASH and NEWSEXTRA. Get additional information about what is happening in the world of cleanrooms with our printed YEARBOOK. And find out who the cleanroom EXPERTS are with our directory.

HJM PMS Systec & Solutions GmbH Piepenbrock