Low differential pressures precisely measure
The differential pressure transducers of the series of D269 are
available with measuring range between ±25 and ±2500 Pa. With an
accuracy of ±0,15 they % werden also high requirements for accuracy
fairly. With the development of this series special value on one
einfache Installation the sensor one put. By the assembly on DIN rails
and the removable process connection is ready for use in few minutes.
For calibration the transducer knows the mechanically linked up
high-grade steel diaphragm from the process connection and the
connection wiring simply and solved without aids werden. gets over
overloading to 14 kPa with system pressures of up to 70 kPa. By an
active compensation the temperature error within the range between -6
and +60 °C only 0.02 %FS/K amounts to. Enterprises will can the
transducer at not-stabilized DC voltages between 14 and 30 V, it is
against polarity geschuetzt. Â
PCB Piezotronics GmbH
41836 Hückelhoven
Germany